My Battery Is Draining Overnight Even When Nothing Is Running — Why?

Your battery SOC is lower in the morning than it was when you went to bed, even though you did not think anything was running. Here is why this happens.

Battery Updated October 2026 3 min read

Your Home Always Uses Some Electricity Overnight

Even a home that appears to have everything off overnight uses a significant amount of electricity from standby and continuous loads. Common overnight draws include:

  • Wi-Fi router and modem: 5 to 15W continuously
  • Smart TV on standby: 1 to 5W
  • Multiple set-top boxes or streaming devices: 10 to 20W each
  • Computer power supplies: 5 to 15W on standby
  • Refrigerator: 50 to 200W cycling
  • Freezer (if separate): 30 to 100W cycling
  • Security system: 5 to 20W continuously
  • Pool pump (if running overnight): 750 to 1500W
  • Hot water system on controlled load charging overnight: 2400 to 3600W for 1 to 4 hours
  • Electric oven clocks, microwave clocks, appliance standby: 5 to 30W

A typical Australian home uses 1 to 3 kWh of electricity overnight even with no lights or active appliances. On a 10 kWh battery, that is 10 to 30% of charge drained overnight without any obvious usage.

The Battery Operating Mode Determines Overnight Behaviour

Self-consumption mode: The battery discharges to supply home loads overnight, drawing from the battery until it reaches the minimum discharge level (often 10 to 20%). This is normal and by design.

Time of Use mode: The battery may be programmed to discharge at certain times and hold charge at other times. If the battery is discharging during off-peak overnight hours when you expected it to hold charge, review the time schedule settings in your app.

Backup reserve mode: If you have a backup reserve set, the battery will not discharge below that reserve level. Energy above the reserve will still discharge to supply overnight loads.

How Much Should My Battery Discharge Overnight?

A rough guide:

  • Fridge, router, and basic standby loads: approximately 0.5 to 1 kWh overnight
  • Adding a pool pump running 8 hours: approximately 6 to 12 kWh additional
  • Adding hot water system charging overnight: approximately 2 to 4 kWh additional

If your battery is discharging much more than expected and you cannot account for the overnight load, use the monitoring app to review the consumption graph in 30-minute intervals for overnight hours. This will show when the large draw is occurring.

The Battery Is Discharging but There Is No Grid Import

If the battery is discharging overnight but the monitoring app shows no grid import and no apparent home loads, check whether the monitoring app’s self-consumption figure accounts for all loads correctly. Some monitoring setups may not capture all consumption.

Call AEU

Call AEU on 1300 996 917 if:

  • The overnight battery drain is much higher than can be accounted for by known loads
  • You want help reading the monitoring app consumption data
  • You want to change the operating mode to reduce overnight discharge

Related articles

Did this fix it?

If the fault is still there, lodge a ticket with your system type, install date and any fault code showing. A technician will call you within one business day.

Lodge a ticket →
Free · No obligation

Planning a new energy upgrade?

Tell us your postcode and what you are considering. We will confirm which rebates your property qualifies for and what comes off the price — no cost, no obligation.

Takes about 60 seconds
Rebates come off the price up front
One team from design to commissioning
Or call 1300 996 917
Check my rebate eligibility

Talk to our team about your property and the rebates that apply.

Call 1300 996 917 Send an enquiry →