Can I Add More Battery Storage to My GoodWe System?

You want to add more battery storage to your existing GoodWe system. Here is how GoodWe ESA batteries can be expanded and what is required.

Battery Updated October 2026 3 min read
Quick answer

Yes. GoodWe ESA batteries are designed as stackable modules. If you have a GoodWe ET, EHB, or Omniverse hybrid inverter with an existing ESA battery, additional ESA modules can be added to increase total storage capacity. The maximum number of modules and total capacity depends on your specific inverter model and firmware version.

GoodWe ESA Battery Series

GoodWe ESA batteries are high-voltage LFP (lithium iron phosphate) modules. Common models in Australia:

  • ESA 2.4: 2.4 kWh per module
  • ESA 3.0: 3.0 kWh per module
  • ESA 5.0: 5.0 kWh per module
  • ESA 7.2: 7.2 kWh per module
  • ESA 10: 10 kWh per module

Newer systems may use the Lynx Home F series battery which is a separate product line. Confirm your current battery model in SEMS+ before purchasing an expansion module.

Maximum Capacity Per Inverter

GoodWe inverter maximum connected battery capacity (approximate, varies by firmware):

  • GoodWe 5 kW ET (GW5048-ET): typically supports up to 30 kWh total ESA capacity
  • GoodWe 6 kW ET (GW6048-ET): similar range
  • GoodWe 8 kW ET (GW8048-ET): up to 30 to 50 kWh depending on firmware
  • GoodWe 10 kW ET (GW10048-ET): up to 30 to 50 kWh
  • GoodWe EHB series: varies by model; confirm with AEU

These limits are hardware and firmware dependent. Call AEU on 1300 996 917 to confirm the maximum capacity for your specific inverter before purchasing expansion modules.

What Is Required to Add a Battery Module

Adding an ESA module is not a customer self-install. It requires:

1. A licensed electrician: Battery module connections involve high-voltage DC circuits. This is electrical work that must be performed by a licensed electrician with appropriate battery storage experience.

2. Compatible ESA module: The new module must be compatible with your existing ESA battery stack and inverter firmware. Mixing older and newer ESA generations on the same stack may require a firmware update or may not be possible.

3. SEMS+ configuration: After adding the module, the battery configuration in SEMS+ must be updated to reflect the new total capacity. Minimum SOC settings, backup reserve, and TOU schedules may need to be reviewed.

4. Potentially: a firmware update: Some GoodWe inverter firmware versions have limits on battery stack size. A firmware update may be required before the additional module is recognised.

Impact on EPS Backup Duration

Adding battery capacity directly extends EPS backup duration. If you currently have 5 kWh of usable capacity and add a second 5 kWh module:

  • Total usable capacity: approximately 10 kWh
  • EPS backup at 500W load: approximately 20 hours (was approximately 10 hours)
  • EPS backup at 1,000W load: approximately 10 hours (was approximately 5 hours)

If extending backup duration is a primary goal: confirm the EPS changeover circuit is installed and EPS is enabled in SEMS+ before adding capacity.

Cost Considerations

AEU can provide a current quote for ESA battery expansion. Call AEU on 1300 996 917 to discuss your current system configuration, the expansion capacity available, and a quote for supply and installation.

Alternative: GoodWe Lynx Home F System

If your current GoodWe inverter is not compatible with additional ESA modules (for example, it has reached its maximum battery capacity), an alternative is the GoodWe Lynx Home F system, which uses a separate battery architecture. Compatibility between inverter and battery systems should be confirmed by AEU before any purchase.

When to Call AEU

Call AEU on 1300 996 917 to:

  • Confirm how much additional battery capacity your existing GoodWe inverter supports
  • Receive a quote for ESA battery expansion
  • Schedule installation of additional battery modules
  • Confirm compatibility of new ESA modules with your existing battery stack and inverter firmware

Related articles

Did this fix it?

If the fault is still there, lodge a ticket with your system type, install date and any fault code showing. A technician will call you within one business day.

Lodge a ticket →
Free · No obligation

Planning a new energy upgrade?

Tell us your postcode and what you are considering. We will confirm which rebates your property qualifies for and what comes off the price — no cost, no obligation.

Takes about 60 seconds
Rebates come off the price up front
One team from design to commissioning
Or call 1300 996 917
Check my rebate eligibility

Talk to our team about your property and the rebates that apply.

Call 1300 996 917 Send an enquiry →