Solar Victoria rebate round ends in 00d 00h 00m 00s Only 7 installer spots left this month

Understanding Your Switchboard: Solar Breakers, Battery Breakers, and What Not to Touch

Your switchboard has additional circuit breakers installed with your solar or battery system. Here is what each one does, which ones you can safely reset, and which ones need a professional.

Battery Updated October 2026 5 min read
Quick answer

When a solar system, battery, or EV charger is installed, one or more additional circuit breakers are typically added to the switchboard. Understanding what each one does helps you respond correctly if one trips.

Solar Circuit Breaker (AC Side)

The solar inverter connects to the switchboard via a dedicated circuit breaker or RCBO (Residual Current Circuit Breaker with Overcurrent protection). This breaker:

  • Protects the wiring between the inverter and the switchboard
  • Disconnects the inverter from the grid when switched off
  • Is typically labelled Solar, PV Inverter, or Fronius (or the inverter brand name)

If this breaker trips: Turn the breaker off fully, wait 30 seconds, then switch it back on. If it trips immediately again: do not reset it a second time. Call AEU on 1300 996 917. A repeatedly tripping solar breaker may indicate a fault in the inverter or the AC wiring.

Safe to reset once: Yes, if there is no visible fault.

Battery Circuit Breaker

The battery system connects to the switchboard via a dedicated breaker, often labelled Battery, ESS (Energy Storage System), or the battery brand name. This breaker:

  • Disconnects the battery from the home wiring
  • Some battery systems also have a separate breaker at the battery enclosure itself

If this breaker trips: Check the battery indicator lights for a fault condition before resetting. If no fault is visible on the battery: reset the breaker once. If it trips again: call AEU on 1300 996 917.

Safe to reset once: Yes, if there is no fault indicated on the battery unit itself.

EPS (Backup) Sub-Board Breakers

If your battery installation includes an EPS (Emergency Power Supply) backup circuit: a separate sub-board or a set of dedicated breakers was installed. These are the circuits that receive power from the battery during a grid outage.

The EPS circuits are selected to cover the most important loads: typically lights, power points, fridge, and possibly a few other key circuits. The rest of the house is not on the backup sub-board.

If backup power did not cover a specific appliance during a power outage: That appliance is likely not on the EPS sub-board. This is by design. Call AEU on 1300 996 917 if you want to discuss which circuits are backed up and whether any changes are possible.

EPS isolator or changeover switch: The changeover between grid and battery backup is handled by an automatic transfer switch (ATS) or inverter relay. There is no manual action required during a power outage. If the changeover does not happen automatically: call AEU on 1300 996 917.

EV Charger Circuit Breaker

The EV charger (wallbox) has a dedicated circuit breaker or RCBO, typically labelled EV Charger or the charger brand name. This breaker:

  • Protects the cable running to the EV charger
  • Is typically rated at 20A, 25A, or 32A depending on the charger model

If this breaker trips while charging: Turn the breaker off, unplug the vehicle from the charger, wait 30 seconds, then reset the breaker and try again. If the breaker trips every time charging is attempted: do not continue resetting. Call AEU on 1300 996 917. A repeatedly tripping EV charger breaker indicates a fault in the charger, vehicle, or wiring.

Safe to reset once: Yes, after disconnecting the vehicle.

Main Switch

The main switch (or mains switch) disconnects all power to the entire house from the grid. It does not disconnect solar panels (which remain energised while there is daylight) and may not disconnect the battery if the battery has its own AC connection.

In an emergency: Turning the main switch off removes grid power from the house but does not make the solar system safe. Inform emergency services that there is a solar system present.

What Never to Do at the Switchboard

Do not open the switchboard enclosure beyond flipping breakers. The wiring inside the switchboard is installed by a licensed electrician and must only be modified by a licensed electrician.

Do not remove the cover of the switchboard. The internal wiring is exposed when the cover is off and can cause electrocution.

Do not attempt to add or modify circuit breakers yourself. All switchboard work requires a licensed electrician.

Do not reset a breaker more than once without knowing why it tripped. Repeated resets can cause the breaker to fail and can allow a fault condition to worsen.

Labelling Your Switchboard

If the breakers in your switchboard are not labelled (or poorly labelled), it can be difficult to identify which breaker to turn off in an emergency. AEU recommends asking for correct labelling of all breakers as part of any installation service. If the solar or battery breakers are not clearly labelled: call AEU on 1300 996 917 to arrange for correct labels to be fitted.

When to Call AEU

Call AEU on 1300 996 917 if:

  • A solar, battery, or EV charger breaker trips repeatedly
  • You are unsure which breaker belongs to which system
  • The EPS backup circuit did not activate during a grid outage
  • The switchboard shows scorch marks, a burning smell, or any sign of heat damage
  • You want the backup (EPS) circuits reviewed or additional circuits added to the backup sub-board

Related articles

Did this fix it?

If the fault is still there, lodge a ticket with your system type, install date and any fault code showing. A technician will call you within one business day.

Lodge a ticket →
Free · No obligation

Planning a new energy upgrade?

Tell us your postcode and what you are considering. We will confirm which rebates your property qualifies for and what comes off the price — no cost, no obligation.