I Have Three-Phase Power — How Does Solar and Battery Work on My Property?

Your property has three-phase power and you want to understand how solar and battery systems work with it, or you have an issue with one phase not working. Here is how three-phase solar and battery systems work in Australia.

Battery Updated October 2026 5 min read
Quick answer

Three-phase power delivers electricity across three separate supply conductors, each carrying AC current at 120 degrees out of phase with the others. In Australia, each phase delivers approximately 230 to 240 volts. Three-phase supplies are common in larger homes, properties with three-phase appliances (large air conditioners, ducted systems, pool equipment, workshop machinery), and most commercial premises. If your switchboard has three rows of circuit breakers (not just one or two), you likely have three-phase power. You can confirm by checking with your DNSP or electrician.

Single-Phase Inverter on a Three-Phase Property

A single-phase solar inverter (such as a GoodWe ET, Fronius GEN24, or Sungrow SH series) can be installed on a three-phase property. The inverter connects to one of the three phases.

What works:

  • The inverter produces solar power normally on its connected phase
  • Export to the grid works normally
  • The battery charges and discharges normally
  • Self-consumption works for appliances on all three phases (the grid interconnects across phases at your meter)
  • Your electricity bill self-consumption calculation is across all phases on most modern smart meters

What does not work:

  • Backup power (EPS) during a grid outage: a single-phase inverter with a backup circuit can only back up the phase it is connected to. Appliances wired to the other two phases will have no power during an outage.
  • If your household has critical three-phase appliances (a large ducted air conditioner, a lift, workshop three-phase equipment), those cannot be backed up by a single-phase system.

Three-Phase Inverters

A three-phase inverter (such as the GoodWe GW series three-phase, Fronius Symo GEN24, Sungrow SH-T series, or SolarEdge Energy Hub three-phase) connects to all three phases simultaneously.

Advantages:

  • Export is balanced across all three phases
  • Backup power during a grid outage can cover all three phases (with appropriate EPS configuration)
  • Required for properties where the DNSP mandates three-phase export balancing
  • Better suited to properties with heavy three-phase loads

When is a three-phase inverter required? Some DNSPs (including some Ausgrid, AusNet, and Energex zones) require a three-phase inverter on three-phase connections for systems above a certain size. AEU will design accordingly. If you have been told you need a three-phase inverter, this is why.

Three-Phase Battery Systems

For backup of three-phase appliances, you need either:

  • A three-phase hybrid inverter with a battery that supports three-phase EPS output, or
  • Three single-phase inverter and battery systems (one per phase), which is significantly more complex and expensive

Three-phase batteries include:

  • Sungrow SBR/SBH batteries with the SH-T series three-phase inverter
  • GoodWe three-phase compatible battery configurations
  • Fronius Symo GEN24 Plus with BYD HVS battery
  • SolarEdge Energy Hub three-phase with SolarEdge Home Battery
  • Sigenergy SigenStor three-phase

If you have a three-phase property and your system uses a single-phase battery, you cannot back up three-phase appliances during an outage.

My Solar Is on One Phase but My Bill Shows Import on Other Phases

This is a common and expected situation with single-phase solar on three-phase supply.

Your solar inverter offsets consumption on its connected phase. However, a three-phase property typically has loads spread across all three phases. Appliances on phases two and three cannot directly use solar from phase one (the grid routes it, but there is a timing and metering interaction).

On time-of-use tariffs with interval metering, this phase mismatch can result in visible grid imports on phases two and three even during peak solar production. The net effect on your bill depends on how your retailer calculates net metering across phases (aggregate metering vs per-phase metering).

If you believe your bill does not correctly reflect your solar self-consumption, call AEU on 1300 996 917 to review your metering configuration and system design.

I Have Three-Phase Power and My EV Charger Is Three-Phase

Three-phase EV chargers (22kW, Type 2) draw from all three phases simultaneously. If your solar system is single-phase and your EV charger is three-phase, the solar system cannot directly offset the three-phase EV charger draw in the same way it would for a single-phase appliance.

For optimal solar self-consumption with EV charging on a three-phase property: a three-phase inverter with solar-aware EV charging (such as the Fronius Wattpilot on a Fronius three-phase system, or the GoodWe EV charger on a GoodWe three-phase system) is the most effective configuration.

One Phase Has No Power and Solar Is Not Producing

If a single phase at your property loses supply:

  • Single-phase appliances on that phase will lose power
  • A single-phase solar inverter on that phase will shut down (anti-islanding protection per AS/NZS 4777.2)
  • Other phases remain live
  • Your battery (if single-phase) will shut down

This indicates a partial grid outage or a fault on that phase. Contact your DNSP:

  • AusNet Services: 13 00 360 795
  • Jemena: 13 63 63
  • Powercor: 13 22 06
  • Energex: 13 12 53
  • Ausgrid: 13 13 65

When to Call AEU

Call AEU on 1300 996 917 if:

  • Your three-phase solar system is only producing on one or two phases
  • You want to add battery backup and need to understand what three-phase backup requires
  • Your electricity bill does not appear to correctly reflect solar self-consumption across phases
  • You want to add a three-phase EV charger and need to understand the interaction with your existing system

Related articles

Did this fix it?

If the fault is still there, lodge a ticket with your system type, install date and any fault code showing. A technician will call you within one business day.

Lodge a ticket →
Free · No obligation

Planning a new energy upgrade?

Tell us your postcode and what you are considering. We will confirm which rebates your property qualifies for and what comes off the price — no cost, no obligation.

Takes about 60 seconds
Rebates come off the price up front
One team from design to commissioning
Or call 1300 996 917
Check my rebate eligibility

Talk to our team about your property and the rebates that apply.

Call 1300 996 917 Send an enquiry →