EV Charger Electrical Basics
All AC home EV chargers (including zappi, Evnex, Fronius Wattpilot, Tesla Wall Connector) charge via a dedicated circuit in your switchboard. They draw AC power and your car’s onboard charger converts it to DC for the battery.
Single-phase charging power levels:
- 6A x 230V = 1.38 kW (minimum legal charge current in Australia)
- 10A x 230V = 2.3 kW
- 16A x 230V = 3.68 kW
- 20A x 230V = 4.6 kW
- 32A x 230V = 7.36 kW (maximum common home charge rate, single phase)
Three-phase charging power levels:
- 16A per phase x 400V (three phase) = 11 kW
- 32A per phase x 400V = 22 kW (maximum common home three-phase charge rate)
The actual charge rate depends on the car’s onboard charger capacity. Many EVs accept up to 7 kW single-phase or 11 kW three-phase, but some accept only 3.6 kW or 4.6 kW regardless of what the charger supplies.
Circuit Breaker Requirements
EV chargers require a dedicated circuit with correct circuit breaker sizing. The charger draws continuous current at or near its rated capacity.
AS/NZS 3000 requires: a continuous duty load (such as an EV charger) must not exceed 80% of the circuit breaker rating over time, or the wiring must be rated to 125% of the load.
Typical circuit breaker sizing:
- 7 kW (32A) single-phase charger: dedicated 40A or 32A circuit breaker, wired with 6 mm or 4 mm cable
- 22 kW (32A three-phase) charger: dedicated 3-phase 40A circuit breaker
- 3.6 kW (16A) single-phase charger: dedicated 20A circuit breaker
If the EV charger circuit breaker is tripping:
- The circuit breaker may be undersized for the continuous load
- The wiring may be undersized
- The overall switchboard main switch or meter fuse may not have sufficient capacity
- There may be another fault on the circuit (earth fault, arc fault)
Call AEU on 1300 996 917 if the EV charger circuit breaker trips. This requires a licensed electrician to diagnose.
Load Management
Load management is a feature in some EV chargers that reduces the EV charging current when other large loads are running simultaneously, to prevent the main circuit breaker from tripping.
Example without load management: main switch is 63A. EV charger uses 32A. Air conditioner uses 15A. Oven uses 10A. Total = 57A. If the family is cooking dinner on a hot day with the AC running while the car charges: total load approaches the main switch limit.
With load management: the EV charger detects (via a CT clamp or energy management system) the total home load and reduces its charge current so the combined draw stays below the main switch rating. The EV charges more slowly but the circuit does not trip.
Load management must be configured at installation. If your charger has load management capability but it does not seem to be working (main switch trips when charging): call AEU on 1300 996 917.
Three-Phase EV Charging — Does Your Setup Support It?
Three-phase EV charging at 11 or 22 kW requires all three of the following:
- Three-phase power supply at your property many Australian homes are single-phase. Three-phase supply has three active wires at the meter (and three circuit breakers in the switchboard). Call your electricity retailer or DNSP to confirm if unsure.
- A three-phase compatible EV charger most home chargers sold in Australia are single-phase (7 kW). Three-phase chargers are available but are less common. Confirm the charger specification.
- A vehicle that accepts three-phase AC charging not all EVs support three-phase AC charging. Common three-phase AC charging capable EVs in Australia include Renault Zoe (22 kW), some Tesla Model 3 variants (11 kW), Polestar, Hyundai Ioniq 6 (11 kW), Kia EV6 (11 kW), BMW i4, and others. Many EVs accept only single-phase up to 7 kW. Check your vehicle specification.
If you have three-phase power and are considering a three-phase charger: call AEU on 1300 996 917 to assess the correct charger and installation requirements.
Charging Speed — Why Is My Car Charging Slower Than Expected?
If the car is charging slower than the charger’s rated maximum:
- The vehicle's onboard charger limits the rate a 7 kW charger connected to a car that accepts only 3.6 kW will charge at 3.6 kW. The car dictates the maximum rate.
- Solar ECO mode is limiting charge rate if the charger is in solar or ECO mode and solar output is low, the charge rate is reduced to match available solar.
- Load management is active another high load in the home is triggering load management and reducing the EV charge rate.
- The charger is throttled by temperature or load some chargers reduce output in high ambient temperatures or after extended full-rate sessions.
- Incorrect current limit setting most EV chargers allow the maximum current to be set below their maximum. Check the app or charger settings to confirm the current limit is set to the maximum your installation supports.
Multiple EVs and a Single Charger
If you have more than one EV and only one charger: the charger can only charge one vehicle at a time. The first car connected charges, and the second must wait.
For households with two EVs: two chargers with load sharing (both chargers coordinate to share the available current) is the most efficient solution. Both charge simultaneously at reduced rates rather than one at full rate and one waiting. Some charger brands (such as zappi) support multi-charger load sharing via their hub. Call AEU on 1300 996 917 to assess a dual-charger setup.
When to Call AEU
Call AEU on 1300 996 917 if:
- The EV charger circuit breaker trips when charging starts or during charging
- Load management is not correctly preventing the main switch from tripping
- You want to upgrade to three-phase charging
- You want to add a second EV charger with load sharing
- Charging speed is significantly below what you expect and settings appear correct