Your switchboard has several different types of protective devices: MCB (Miniature Circuit Breaker): Protects against overloads and short circuits. Usually black or white switches labelled with a circuit name and amp rating (10A, 16A, 20A, 32A). Trips to the middle position when fault occurs. RCD (Residual Current Device): Also called a safety switch. Protects people from electric shock by detecting earth leakage (when current takes an unintended path, such as through a person). Usually has a Test button on the front. Trips fully off when fault occurs. RCBO (Residual Current Breaker with Overcurrent): Combines both MCB and RCD functions in one device. Protects against both overloads and earth leakage. Common in modern switchboards. Main switch: Turns off all power to the house. Does not detect faults.
How to Reset a Tripped MCB
- Turn the tripped MCB to fully off
- Then switch it back to on
- If it stays on, the fault has cleared
- If it trips again immediately, stop. Do not reset again.
An MCB that trips immediately on reset indicates a persistent fault on that circuit — a short circuit, failed appliance, or wiring fault. Continued resetting will not fix the problem and risks damaging wiring.
How to Reset a Tripped RCD or RCBO
- Turn off all appliances on the affected circuit (to make it easier to identify which one caused the trip)
- Push the RCD or RCBO to the fully off position
- Push it back to on
- If it holds, turn appliances back on one at a time to identify which one caused the trip
- If the RCD trips when a specific appliance is turned on, that appliance has developed an earth fault — take it for repair or disposal
If the RCD trips with nothing plugged in, there is a wiring fault in the circuit. Call a licensed electrician.
How Many Times Can I Reset?
You can attempt one reset per event. If the breaker or RCD trips again:
- Stop resetting
- Leave the device in the off position
- Investigate what is different (new appliance, recent wet weather, recent work done)
- Call a licensed electrician or call AEU on 1300 996 917
There is no safety benefit to resetting multiple times. The protective device is telling you something is wrong.
Solar and Battery Circuit Specific Rules
Solar AC circuit breaker: Can be reset once after a power outage or single trip event. If it trips again when the solar inverter tries to reconnect, do not reset. Call AEU on 1300 996 917.
Battery RCBO or RCD: If the battery circuit safety switch trips, reset once. If it trips again, do not reset. The battery systems carry DC voltage and high currents. Call AEU on 1300 996 917.
DC isolator for solar panels: This is a switch between your roof panels and the inverter. If you are turning off the system for safety, turn this off. But if it has failed or damaged, do not attempt to repair it yourself — panels generate DC voltage any time there is light. Call AEU on 1300 996 917.
Situations Where You Should Not Touch Any Switches
If you smell burning: Turn off the main switch if safe to do so, leave the property, call 000 if there is any sign of fire.
After flooding or water damage to the switchboard: Do not touch the switchboard. Call a licensed electrician.
If you hear crackling or buzzing from the switchboard or wiring: Do not touch. Call a licensed electrician.
If a circuit breaker is hot to touch: This indicates a fault. Do not touch the breaker. Turn off the main switch if safe and call an electrician.
For solar and battery related circuit concerns, call AEU on 1300 996 917.