The Tesla Powerwall 3 differs from the Powerwall 2 in a key way: the Powerwall 3 has an integrated solar inverter built in. This means solar panels connect directly to the Powerwall 3 rather than to a separate inverter. The Powerwall 3 manages both solar conversion and battery storage in one unit. If you have a Powerwall 3, your system has no separate string inverter. All solar wiring runs directly to the Powerwall 3 unit.
Common Tesla App Alerts — Powerwall 3
Grid Disconnected: The Powerwall 3 has detected the grid supply is unavailable. If there is a power outage, this is expected. The Powerwall 3 switches to backup mode and supplies your home from battery. When grid is restored, it reconnects automatically after the AS/NZS 4777.2 delay (60 seconds to 5 minutes).
If you have power at your home but the app says Grid Disconnected, the sensing circuit may have an issue. Call AEU on 1300 996 917.
System Offline (Not Connected): The Powerwall 3 cannot communicate with the Tesla servers. This is a Wi-Fi or internet issue, not a system performance issue. The Powerwall continues to operate normally — it just is not reporting to the app.
- Check your home internet is working
- Check your home Wi-Fi router
- The Powerwall 3 connects via its own Wi-Fi — if your network name or password changed, the Powerwall needs reconfiguration. Call AEU on 1300 996 917.
Solar Not Producing: The Tesla app shows solar is not generating. Before assuming a fault:
- Is it daytime with adequate sunlight?
- Check the Powerwall 3 display (if accessible) for any fault indicators
- Check for any storm damage to solar panels
- If it is a clear day and solar has been zero for more than 2 hours, call AEU on 1300 996 917
Powerwall Not Charging: See the Powerwall not charging from solar article for mode explanations (Self-Powered vs Backup Only vs Time-Based Control). These apply equally to Powerwall 2 and 3.
Backup Reserve Not Maintained: The battery dropped below the backup reserve you set. This happens when:
- Grid was unavailable and the battery supplied the home until depleted
- The battery is performing at lower than expected capacity (may indicate a warranty issue if capacity has dropped below 70% of rated output)
Firmware Update in Progress: Tesla remotely updates the Powerwall firmware. During an update the unit may appear offline in the app for 15 to 30 minutes. Do not disturb the system during updates.
Powerwall 3 Is Not Charging From Solar on a Clear Day
- Check the Tesla app energy flow screen — is solar production showing any kW output?
- If solar shows zero on a clear day, check whether the Powerwall 3 display shows any fault
- Check the DC isolators between the solar panels and the Powerwall 3 are in the on position
- If the DC isolators are on and the Powerwall 3 is powered but shows no solar production after 30 minutes on a clear day, call AEU on 1300 996 917
Powerwall 3 Backup During a Blackout
The Powerwall 3 supports whole-home backup (when the gateway and switchboard configuration allows) or partial backup depending on the installation design. If your Powerwall 3 did not provide backup during a blackout:
- Was the battery SOC above the backup reserve at the time?
- Is the home wired for whole-home or partial backup? (Check the installation documentation or ask AEU)
- Was there an active fault in the app at the time of the outage?
Call AEU on 1300 996 917 if backup did not activate with adequate charge available.