My Electric Hot Water System Is Not Heating or Is Running Out — Is It on an Off-Peak Tariff and What Does That Mean?

Your electric storage hot water system is not heating at certain times of day or you are running out of hot water at specific times. Your system may be on an off-peak (controlled load) electricity tariff. Here is how this works and what it means for your hot water.

Hot Water Updated October 2026 5 min read
Quick answer

An off-peak hot water tariff (also called Controlled Load 1 or CL1, or sometimes Controlled Load 2 or CL2 in Victoria) is a lower-cost electricity rate available for hot water heating that operates at a reduced price in exchange for the electricity distributor controlling when the heater can run. Your hot water system's heating element is connected to a separate circuit at the switchboard that the distributor can switch on and off remotely. The heater runs during designated off-peak periods (typically overnight or during periods of low grid demand) at a lower electricity rate. In Victoria: Controlled Load 1 (CL1) typically operates for at least 8 hours per day, usually overnight (approximately 11 pm to 7 am, though exact times vary by distributor and may shift seasonally). Some distributors also operate shoulder or secondary controlled load periods.

This Is Why Your Hot Water Runs Out in the Afternoon

If your system heated overnight and you have used all the stored hot water by afternoon: the system will not reheat until the next controlled load period begins overnight.

This is normal behaviour for an off-peak system. The tank size is designed to store enough hot water heated overnight to last the following day.

If you regularly run out:

  • The tank may be undersized for the household
  • Demand has increased (more occupants, more usage)
  • The overnight heating period was insufficient to fully heat the tank (element fault, thermostat issue, or reduced controlled load hours)

How to Tell If Your System Is on Controlled Load

Check the switchboard: A controlled load circuit will have a separate circuit breaker labelled CL1, CL2, Off-Peak, Economy, Tariff 31, or Ripple. It is separate from the main hot water circuit breaker. Some properties have two circuit breakers for the hot water system (one for off-peak, one that allows anytime use).

Check your electricity bill: An off-peak or controlled load line item will appear on your bill if you are using this tariff. The rate for controlled load electricity is lower than the standard peak rate.

Call your electricity retailer: Your retailer can confirm whether your property has a controlled load circuit and when it operates.

My Hot Water Has Stopped Heating Entirely

If the hot water stopped heating completely (not just running out in the afternoon but no hot water at all for a full cycle):

Circuit breaker trip: Check both the hot water circuit breaker AND the controlled load circuit breaker (if separate). A tripped circuit breaker on the controlled load circuit prevents the heater from running during its off-peak window.

Element failure: The electric heating element in the tank has failed. A failed element means the tank does not heat at all, regardless of when the controlled load period runs. Signs: water is cold after a full overnight controlled load period, circuit breaker has not tripped, power to the unit is confirmed. Call AEU on 1300 996 917.

Thermostat failure: The thermostat controls when the element turns on and off. A failed thermostat can leave the element permanently off (cold water) or permanently on (element overheats and a safety fuse blows). Call AEU on 1300 996 917.

Controlled load circuit no longer connected to the element: If work has been done on the switchboard or the property wiring: the controlled load circuit may no longer be connected to the hot water element. The element has anytime power only (higher electricity cost) or no power. Call AEU on 1300 996 917.

Boosting Hot Water Outside Off-Peak Hours

Many electric hot water systems with a controlled load circuit also have a boost capability: a second connection that allows the element to run on standard tariff electricity outside the off-peak window, at higher cost, for emergency use.

If your switchboard has two circuit breakers for the hot water system:

  • Controlled load breaker: powers the element during the off-peak window only
  • Boost or anytime breaker: powers the element at any time (higher tariff)

If you need hot water urgently outside the off-peak window: turning on the boost breaker will allow the element to heat water immediately. Turn it back off after the hot water has recovered to avoid incurring standard tariff charges for future heating.

Note: some systems have only the controlled load circuit with no boost option. In this case: you cannot override the timing without an electrician adding a boost circuit.

Solar Hot Water Diverter and Controlled Load

If you have solar panels and a solar diverter (a device that uses solar surplus to heat the hot water element during the day), the controlled load circuit and the diverter may operate on the same element. In this case:

  • Solar diverter heats the tank during the day using surplus solar
  • Controlled load tops up overnight if solar heating was insufficient

This is an efficient combination that reduces reliance on the overnight controlled load.

When to Call AEU

Call AEU on 1300 996 917 if:

  • There has been no hot water after a full overnight controlled load period with the circuit breaker on
  • You suspect the element or thermostat has failed
  • You want to add a boost circuit or solar diverter to your existing hot water system
  • You want to upgrade from a controlled load electric storage system to a heat pump system
  • The controlled load circuit breaker is tripping

Related articles

Did this fix it?

If the fault is still there, lodge a ticket with your system type, install date and any fault code showing. A technician will call you within one business day.

Lodge a ticket →
Free · No obligation

Planning a new energy upgrade?

Tell us your postcode and what you are considering. We will confirm which rebates your property qualifies for and what comes off the price — no cost, no obligation.

Takes about 60 seconds
Rebates come off the price up front
One team from design to commissioning
Or call 1300 996 917
Check my rebate eligibility

Talk to our team about your property and the rebates that apply.

Call 1300 996 917 Send an enquiry →