How Heat Pump Hot Water Systems Work in Cold Weather
A heat pump hot water system extracts heat energy from the surrounding outdoor air to heat the water in the storage cylinder. This is the same principle as a refrigerator in reverse.
In warm weather (above 15°C), heat pump hot water systems are highly efficient: typically extracting 3 to 4 units of heat energy for every 1 unit of electricity used. This is the efficiency advantage over conventional electric element hot water.
In cold weather, the available heat energy in the outdoor air reduces. As the temperature drops:
- Efficiency reduces The heat pump must work harder to extract heat from cold air. The COP (coefficient of performance) drops. At 5°C, the efficiency may be 2:1 rather than 3 or 4:1.
- Heating time increases The heat pump takes longer to heat the tank from cold to 60°C.
- Defrost cycles occur In cold, humid conditions, ice forms on the outdoor heat exchange coil. The system must run defrost cycles to melt the ice, during which heating of the water pauses.
Boost Element Operation in Cold Weather
All residential heat pump hot water systems include an electric boost element inside the cylinder as a backup. The boost element is a conventional electric resistance element (identical in principle to a conventional electric hot water service).
The boost element activates automatically when:
- The ambient temperature is too cold for the heat pump to operate at all (typically below 0 to 5°C, varying by model)
- The heat pump cannot meet demand quickly enough and hot water is needed urgently
- The system is in an emergency or boost mode
- The heat pump has a fault and has stopped functioning
Is boost operation in winter normal?
On very cold winter nights (below 5°C in Victoria), some heat pump systems will switch to boost element only because the refrigerant circuit cannot efficiently operate at very low temperatures. This is normal for most standard refrigerant (R410A, R32) heat pump hot water systems.
The CO2 (R744) heat pump systems (Reclaim Energy, Sanden) have a much lower minimum operating temperature (some rated to minus 10°C or below) and are specifically designed for cold climates. Boost operation at Australian winter temperatures should be less common on CO2 systems.
When boost operation is not normal:
- The boost is running continuously even at ambient temperatures above 10°C
- The heat pump compressor is not running at all on mild days
- An error code is present alongside boost-only operation
In these cases: call AEU on 1300 996 917.
Defrost Cycle
When ice forms on the outdoor coil (common in cold, damp conditions), the heat pump automatically runs a defrost cycle:
- The compressor may stop briefly
- The outdoor fan may stop
- Steam or vapour may appear around the outdoor unit as ice melts
- The heat pump temporarily stops heating the water
A defrost cycle typically lasts 5 to 15 minutes. Multiple defrost cycles per day are normal in cold, humid weather. The system restarts heating after each defrost.
Do not be alarmed by defrost cycles. Do not turn the system off during a defrost cycle.
Running Hot Water Out More Quickly in Winter
In winter:
- Hot water demand is typically higher (longer showers, baths, more hot water for cleaning)
- The heat pump takes longer to reheat the tank after a draw-down
- If the heat pump cannot keep up with demand in very cold conditions: the boost element activates
If you regularly run out of hot water in winter:
- Consider activating the boost in the controller for a 1 to 2 hour period in the early morning on very cold days
- Check that the system set temperature is at 60°C (not lower, which reduces the effective stored hot water volume)
- A boost timer can be set to activate automatically overnight in winter months
Minimum Operating Temperature by Common Brands
The minimum ambient temperature for heat pump operation varies by model:
- Rheem MPi/Ambiheat (R410A) Approximately 5°C minimum for heat pump mode
- Stiebel Eltron WWK (R134a) Typically rated to minus 7°C
- Reclaim Energy CO2 Rated to minus 10°C or below
- Sanden CO2 Rated to minus 10°C
- Thermann heat pump (R410A) Approximately 5°C minimum
- Daikin Altherma DHW (R32) Approximately minus 5°C to 0°C depending on model
- Emerald heat pump Approximately 5°C minimum for standard models
Below the rated minimum: the system should automatically switch to boost element only without generating a fault code.
When to Call AEU
Call AEU on 1300 996 917 if:
- The heat pump compressor is not running on days above 10°C (not just cold nights)
- An error code is visible on the controller
- The boost element appears to be the only source of heating across all weather conditions
- Hot water supply has become inadequate across multiple days and the weather is not extremely cold
- The system is less than 2 years old and was adequate last winter but is struggling this winter