Heat pump hot water systems are not silent appliances. They have a fan, a compressor, and refrigerant flowing through copper tubes. All of these produce sound during normal operation. Normal sounds: Fan hum: A continuous low to medium frequency hum from the evaporator fan is normal during all heat pump operation. The fan draws outdoor air across the evaporator coil and runs whenever the heat pump is active. Compressor hum/vibration: The compressor is similar in type to those used in refrigerators and air conditioners. A steady low-frequency hum and some vibration through the floor or wall near the unit is normal. Refrigerant flow sounds: A light gurgling or hissing sound from refrigerant moving through the circuit is normal. You may hear this briefly when the heat pump starts or stops. Defrost cycle sounds: In cold weather (below approximately 7 degrees Celsius), the evaporator coil can frost over and the heat pump performs a defrost cycle. During defrost: you may hear the fan stop, a different refrigerant flow sound, and water dripping as the frost melts. This is normal and lasts 5 to 15 minutes. Expansion and contraction sounds: Hot water in a storage tank causes the tank to expand and contract slightly as it heats. Light ticking or clicking sounds from the tank body are normal.
Sounds That May Indicate a Problem
Rattling or vibrating that has developed recently: If the heat pump has started rattling in a way it did not before: check that the unit is level and that the installation feet or brackets have not loosened. A panel or guard that has come loose can cause rattling. Tighten any accessible screws. If the rattle continues: call AEU on 1300 996 917.
Very loud banging or clanking on startup: Loud mechanical noise on compressor startup can indicate liquid refrigerant in the compressor (liquid slugging). This damages the compressor. Do not continue operating. Call AEU immediately on 1300 996 917.
Grinding or screeching from the fan: A grinding or high-pitched screeching sound from the fan area indicates a fan motor bearing failure. The fan motor requires replacement. Do not continue operating: a failed fan motor can overheat the unit. Call AEU on 1300 996 917.
Hissing or bubbling sounds that are much louder than usual: A significant hissing from the refrigerant circuit (not the normal startup gurgle) can indicate a refrigerant leak. If you also notice reduced heating performance: call AEU. Do not attempt to investigate or fix a refrigerant leak yourself.
Vibration through walls or floors that is causing disturbance: Even normally operating heat pumps can transmit vibration to a building structure if the anti-vibration mounts have deteriorated or the installation is not well isolated. Anti-vibration pads or mounts can reduce this. Call AEU to assess.
Noise and Installation Location
Heat pump hot water systems are rated at approximately 45 to 60 dB at 1 metre distance during normal operation. This is roughly the level of a quiet dishwasher to a normal conversation. Proximity to bedroom windows or walls can make them more noticeable at night.
Most Australian states and territories apply Environmental Protection Authority noise guidelines to heat pump installations. If the unit is too close to a neighbour’s bedroom window: check the installation clearances against manufacturer specifications. AEU can advise on whether relocation is feasible if noise is causing a genuine issue.
When to Call AEU
Call AEU on 1300 996 917 if:
- Loud banging or clanking on startup
- Grinding or screeching from the fan area
- A rattling that has developed recently and cannot be attributed to a loose panel
- You suspect a refrigerant leak (hissing combined with reduced hot water output)
- Vibration is transmitting through the building and causing a nuisance