Solar hot water systems use roof-mounted collectors to capture the sun's heat and transfer it to water in a storage tank. There are two main collector types: Flat plate collectors: A flat panel with a dark absorber plate and glass cover. Common in warmer climates. Less effective in very cold weather. Evacuated tube collectors: A series of glass tubes from which the air has been evacuated. More efficient in cold and cloudy conditions. The heat transfer fluid inside the tubes moves heat to the storage tank. The storage tank is typically at ground level or on the roof (close-coupled systems have the tank directly above or beside the collectors). The system may use either a thermosiphon (passive, no pump) or a pumped circulation system. Booster element: Most solar hot water systems have an electric or gas booster element to supplement heating when solar gain is insufficient (cloudy weather, winter, high demand periods).
No Hot Water: Step-by-Step Checks
Check 1 — Booster Element or Gas Booster
The booster ensures you have hot water even on cloudy days and in winter. If the booster is not working, you will have no hot water on overcast days.
Electric booster: Check the circuit breaker for the hot water system at the switchboard. If the system is on a controlled load (off-peak) tariff, it only heats during off-peak hours. If the controlled load period has not yet occurred: wait until the next off-peak window (typically overnight).
Gas booster (continuous flow booster): Check the gas supply (try other gas appliances), check the isolation valve on the gas pipe is open, and check the booster controller for any fault codes.
Check 2 — Is the Sun Shining?
Solar hot water systems require direct sunlight on the collectors to heat effectively. On overcast days, heating is reduced. The booster should compensate, but if the booster is also not working (see above), you may have no hot water on a cloudy day.
Check 3 — Frost Protection Valve Has Operated
In Victoria, overnight temperatures can drop below freezing, particularly in inland and elevated areas. Most solar hot water systems have a frost protection valve (also called a tempering valve or auto-drain in some systems) that releases a small trickle of water when temperature drops near freezing, preventing the collectors and pipes from freezing.
If the frost valve has operated:
- You may hear a gentle trickle of water from the roof or from the valve itself
- This is normal in cold weather and is a protective function
- If the frost valve continues to trickle when temperatures are not near freezing, the valve has failed and is wasting water. Call AEU on 1300 996 917.
Check 4 — Broken Evacuated Tube
On evacuated tube systems, individual tubes can crack or break. A broken tube is usually visible:
- One tube in the array is white or milky looking rather than dark (the vacuum has been lost and the tube is no longer effective)
- In some cases, the broken tube may have fallen or be visibly out of alignment
A single broken tube reduces system efficiency but does not prevent the remaining tubes from working. Broken tubes should be replaced. Call AEU on 1300 996 917.
Check 5 — Flat Plate Collector Damage
Flat plate collectors can be physically damaged by hail or broken by objects falling on them. Visible signs: cracked or broken glass cover panel. This is an insurance claim. Call AEU on 1300 996 917 for an inspection report.
Check 6 — Pump Failure (Pumped Systems)
If your solar hot water system uses a pump to circulate fluid between the collectors and the tank (rather than thermosiphon), a failed pump will prevent heat transfer.
Signs of a failed pump:
- The collectors heat up normally in the sun (you can feel the top of the collectors being warm through an access panel or the roof surface near the collectors)
- But the tank water remains cold
- The pump is a small device, usually near the tank or in an equipment box, and should hum softly when operating
A failed pump requires replacement. Call AEU on 1300 996 917.
Check 7 — Tempering Valve Fault
All solar hot water systems must have a tempering valve to limit delivered water temperature to 50°C at bathroom fixtures. If the tempering valve has failed or is clogged:
- Hot water may be delivered at the wrong temperature (too hot or only lukewarm)
- Flow rate at taps may be reduced
A failed tempering valve requires replacement by a licensed plumber. Call AEU on 1300 996 917.
Water Temperature Too Hot
Solar hot water tanks can reach very high temperatures (80 to 90°C+) on long sunny days, especially in summer. The tempering valve is supposed to mix cold water into the hot to deliver 50°C at bathroom taps.
If water at the tap is scalding hot:
- The tempering valve may have failed open (passing undiluted hot water)
- Call AEU on 1300 996 917. Delivery of water above 50°C at bathroom fixtures is a safety hazard and is not compliant with AS/NZS 3500.4.
Water Coming from the TPR Valve on the Tank
The tank has a Temperature and Pressure Relief valve that drips during heating (normal thermal expansion) and opens fully if the tank overheats or overpressures (safety shutdown).
A small drip during or after the solar heating cycle is normal. Continuous flow is not. See the TPR valve article for detailed guidance.
Stained or Discoloured Hot Water
If hot water appears yellow, brown, or rust-coloured:
- Older steel tanks can corrode internally. The anode rod (sacrificial anode) is supposed to protect the tank lining. If the anode has been exhausted, corrosion can accelerate.
- Glass-lined (vitreous enamel) tanks are more common and more corrosion-resistant, but are not immune if the lining cracks.
Discoloured water from a solar storage tank often indicates the tank is nearing end of life. Call AEU on 1300 996 917 for an assessment.
When to Call AEU
Call AEU on 1300 996 917 if:
- The booster is working but water is still cold on sunny days (collectors or pump fault)
- A broken evacuated tube is visible (white or milky tube in the array)
- The pump is silent when it should be running
- The frost protection valve continues to run when temperatures are not near freezing
- Water at bathroom taps is scalding hot (tempering valve fault)
- The TPR valve is flowing continuously
- Water from the hot taps is discoloured
- The collectors have been physically damaged by hail or impact


