Thermann manufactures heat pump hot water systems sold in Australia through electrical and plumbing distributors. The system uses a refrigerant heat pump cycle to extract heat from outdoor air to heat water stored in a cylinder. The controller panel is mounted on the cylinder. Thermann heat pump systems include an electric boost element in the cylinder for backup heating when the heat pump cannot meet demand or when operating conditions are outside the heat pump's range.
Before Checking Error Codes
Circuit breaker: Check the circuit breaker for the heat pump at the main switchboard. If it has tripped, reset it. If it trips again immediately: turn it off and call AEU on 1300 996 917.
Cold weather: Thermann heat pumps are designed to operate in ambient temperatures down to approximately 5°C. Below this, the heat pump efficiency reduces significantly. Below approximately 0°C, the system may switch to boost element only. This is normal operation, not a fault.
Defrost cycle: In cold and humid conditions, frost builds on the outdoor coil. The system automatically runs a defrost cycle: the compressor may pause, the outdoor fan may stop, and steam may appear around the unit. This lasts 5 to 15 minutes. Do not interrupt a defrost cycle.
Hot water schedule: If the system is set to operate only during off-peak hours (typically overnight), it will not heat during the day. Check the controller schedule.
Thermann Heat Pump Error Codes
E1 / Ambient Temperature Sensor Fault: The outdoor air temperature sensor has failed. The heat pump cannot correctly control the refrigerant cycle without this sensor.
Power cycle from the circuit breaker (off for 5 minutes, then on). Allow 10 minutes for restart. If E1 returns: call AEU on 1300 996 917.
E2 / Water Temperature Sensor Fault: The temperature sensor in the cylinder has failed. The system cannot determine when the water is adequately heated.
Power cycle. If E2 returns: call AEU on 1300 996 917.
E3 / Coil Temperature Sensor Fault: The sensor on the outdoor heat pump coil has failed. Power cycle. If E3 returns: call AEU on 1300 996 917.
E4 / High Pressure Fault: The refrigerant high-side pressure has exceeded the safe limit. The compressor has stopped.
Check the outdoor unit: is the airflow around the unit obstructed by debris, fencing, or objects? Clear any obstructions and allow 15 to 20 minutes for the unit to cool. Power cycle.
If E4 returns on a day with moderate outdoor temperature and the outdoor unit is clear: call AEU on 1300 996 917.
E5 / Low Pressure Fault: The refrigerant low-side pressure is below the safe operating range. In above-freezing ambient conditions, this usually indicates a refrigerant leak.
Do not continue operating the system with this fault active. Refrigerant loss damages the compressor. Call AEU on 1300 996 917.
E6 / Compressor Overload or Overcurrent: The compressor is drawing excessive current. Power cycle once. If E6 returns: call AEU on 1300 996 917.
E7 / Fan Motor Fault: The outdoor fan motor is not running or not reaching the correct speed. Power cycle once. If E7 returns: call AEU on 1300 996 917.
E8 / Communication Fault: The controller panel cannot communicate with the heat pump unit. Check that the power to the unit is on. Power cycle the full system. If E8 persists: call AEU on 1300 996 917.
E9 / Defrost Fault: The defrost cycle has not completed within the expected time or the coil temperature is not recovering from frost. This may occur in very cold conditions.
Allow the unit to warm up naturally in a sheltered location if possible. If E9 appears consistently in ambient temperatures above 5°C: call AEU on 1300 996 917.
Boost Element on Thermann Systems
Thermann heat pump systems include an electric boost element inside the cylinder. The boost element activates automatically when:
- The ambient temperature is too cold for effective heat pump operation
- Demand has depleted the tank faster than the heat pump can recover
- The unit is in Emergency or Boost mode
If the boost element is running and the heat pump is not: check the controller display. If only the boost element is running and no error is shown, the system may be in a boost-only mode due to cold conditions or a heat pump fault.
The boost element uses significantly more electricity than the heat pump. If the boost has been running for more than 24 hours and the weather is not extremely cold: there may be a heat pump fault that is not displaying an error. Call AEU on 1300 996 917.
Power Cycle Procedure
- Turn the circuit breaker for the heat pump off at the main switchboard
- Wait 5 minutes
- Turn the circuit breaker back on
- Wait 5 to 10 minutes for the unit to complete its restart and self-check sequence
- Check the display for any remaining error code
No Hot Water With No Error Code
- Check the set temperature on the controller. The default is typically 60°C. If it has been reduced: increase it.
- Check the operating schedule. If the system is in timer mode and the timer window has passed without completing a full heat cycle: the water may not have reached temperature.
- Check that the unit is actually running. Listen for the outdoor fan and compressor. If silent during what should be an operating window: the heat pump may have stopped without triggering an error. Power cycle and observe.
- If the unit is running but the water temperature on the controller display is not rising: the heat pump output may be reduced due to very cold ambient conditions. Activate the boost manually for 1 to 2 hours.
When to Call AEU
Call AEU on 1300 996 917 if:
- E5 appears (possible refrigerant leak)
- E6 appears (compressor overcurrent)
- Any error code returns after a single power cycle
- The circuit breaker trips when the unit restarts
- The boost element has been the only source of heating for more than 24 hours outside of cold-weather conditions
- The unit makes grinding, knocking, or abnormal sounds from the compressor
- There is no hot water after a full day with the circuit breaker on and no error displayed