1. Is it set to cooling mode? Check the remote or wall controller. Make sure the mode is Cool (snowflake icon), not Fan Only, Heat, or Dry. The system will not produce cold air in Fan Only or Heat mode. 2. What is the set temperature? If you have set the temperature at 24 degrees Celsius and the room is already at 24 degrees, the system has nothing to do. Try setting it 3 to 4 degrees below the current room temperature. 3. Is the outdoor unit running? Go outside and look at the outdoor unit. If the indoor unit is running (you can hear airflow inside) but the outdoor unit fan is not spinning and the unit is silent, the outdoor unit is not operating. This is a fault. Check the indoor controller for an error code and call AEU on 1300 996 917. 4. Is the air filter blocked? A blocked air filter is the single most common cause of poor cooling in Australian homes. It restricts airflow and can cause the indoor coil to freeze, which stops cooling entirely. For ducted systems: the filter is usually a large mesh panel behind a ceiling return air grille. Pull the grille down (usually spring clips), remove the filter, and check it. If it is covered in grey dust and lint, wash it with water and let it dry completely. For split systems (wall units): the filters are accessed by lifting the front cover of the indoor unit. Two mesh filters will slide out. Wash under water, let dry, replace. 5. Is the outdoor unit blocked? The outdoor unit needs free airflow to reject heat. If it is surrounded by vegetation, garden furniture, or debris, it cannot work efficiently. Clear at least 300mm of space on all sides of the unit. 6. Is the weather extremely hot? Every air conditioner has a rated capacity designed for certain conditions. On days above 40 degrees Celsius with high humidity, a system may struggle to keep up if the house is poorly insulated or has significant unshaded glass. Close blinds and curtains on the sunny side of the house.
The System Is Blowing Warm Air
If the system is blowing air but it is not cold:
- Check that the outdoor unit is actually running (fan and compressor)
- Feel the larger copper pipe going into the outdoor unit — it should be cold
- If the large pipe is not cold and the outdoor unit is running, the system may be low on refrigerant (refrigerant leak)
- Refrigerant leaks require a licensed technician. Call AEU on 1300 996 917.
When to Call AEU
Call AEU on 1300 996 917 if:
- There is an error code on the controller
- The outdoor unit is not running despite the indoor unit being on
- The filter is clean but the system is still not cooling
- The air coming from the vents is not cold at all
- You notice ice forming on the indoor unit or on the copper pipes
- The system is making noises it has not made before