Make sure the system is actually in Heat mode (flame or sun icon on the controller), not Cool, Fan Only, or Dry. Pressing the mode button cycles through the options. In Heat mode the system runs in reverse and produces warm air.
The System Is in Heat Mode but Blowing Cool or Lukewarm Air
The defrost cycle is running. During cold weather, the outdoor unit coil can frost up. The system automatically runs a defrost cycle periodically (typically every 30 to 90 minutes in cold conditions), during which it temporarily reverses to melt the ice. During defrost, the indoor unit will blow cool or ambient-temperature air and the outdoor unit will steam. This is normal and lasts 5 to 15 minutes.
What to check: Wait 15 minutes. If the system returns to producing warm air after the defrost completes, everything is working normally.
The outdoor temperature is very low. Reverse-cycle heat pumps (all ducted and split systems) extract heat from outdoor air. As outdoor temperature drops, heating capacity decreases. At temperatures below approximately 2 to 5 degrees Celsius, many systems run at reduced capacity. Below approximately minus 10 to minus 15 degrees Celsius, some systems will stop heating entirely.
This is a capacity limitation, not a fault. If your area experiences very cold winters and you need reliable heating, contact AEU about selecting appropriate equipment.
The outdoor unit fan is not running. In heat mode the outdoor unit must run to extract heat from outside air. Go outside and check whether the outdoor unit fan is spinning. If the fan is not running, check the controller for a fault code and call AEU on 1300 996 917.
The air filter is blocked. As with cooling mode, a clogged return air filter restricts airflow and dramatically reduces heating performance. Check and clean the filter.
The system is set too low. If the thermostat is set to 20 degrees Celsius and the room is already at 20 degrees, the system will not heat further. Set the temperature higher than the current room temperature.
The System Heats but Then Stops
If the system heats for a while and then stops:
- The room may have reached the set temperature. Check the display.
- The system may be in a defrost cycle — wait 15 minutes.
- If the system has stopped and will not restart, check the controller for a fault code.
Call AEU
Call AEU on 1300 996 917 if:
- There is a fault code on the controller
- The outdoor unit is not running during heating mode (outside a defrost cycle)
- The system has never worked in heat mode since installation
- The air produced is consistently cold even after waiting out any defrost cycles