My Split System Air Conditioner Will Not Turn On — Where Do I Start?

Your split system air conditioner will not turn on at all when you press the remote or the button on the indoor unit. Here is a logical sequence of checks before calling for service.

Heating & Cooling Updated October 2026 4 min read

Step 1: Check the Remote Control First

Before assuming the air conditioner itself has a fault, check the remote control:

  • Replace the remote control batteries. This is the most common reason a unit seems unresponsive. Use new alkaline batteries, not rechargeable batteries in most cases (some remotes require specific voltages).
  • Point the remote directly at the indoor unit receiver (usually a small window or dot at the front of the indoor unit). Ensure nothing is blocking the line of sight.
  • Test the remote using your phone camera: point the remote at the camera and press a button. You should see a flash or glow from the remote's IR emitter in the camera screen. If nothing: the remote has failed.
  • If the remote is confirmed working and the unit still does not respond: continue to the next steps.

Step 2: Check the Indoor Unit Directly

Most split system indoor units have a manual override button (sometimes labelled TEST, ON/OFF, or with a power symbol) on the front or bottom of the unit. Press it. This operates the unit without the remote. If the unit starts on the manual button but not the remote: the remote has failed, not the unit.

If the unit does not respond to the manual button: the unit itself may have no power or has a hardware fault.

Step 3: Check the Power Supply

Indoor unit isolator switch: Many split system indoor units have a dedicated isolator switch on the wall near the unit or in the same room. This is a small switch (not a circuit breaker) that cuts power to the indoor unit. Confirm it is in the ON position.

Circuit breaker at the switchboard: Every split system has a dedicated circuit breaker at the main switchboard. Find the breaker labelled for the air conditioning (it may be labelled AC, AIR CON, or the room it serves). Confirm it has not tripped. If it has tripped: reset it by switching it fully off then back on. If it trips again immediately: there is a fault in the wiring or the unit. Do not keep resetting. Call AEU on 1300 996 917.

Check that the outdoor unit also has power: The outdoor unit may have its own isolator switch near the unit or a separate circuit breaker. Confirm both are on.

Step 4: Check for Timer or Schedule Settings

Many remote controls and app-connected units can be set to a timer or schedule mode that prevents immediate operation. Check:

  • The remote control display for any timer or schedule indicator
  • The manufacturer app (if Wi-Fi connected) for any active schedule that may be blocking the unit
  • Pressing the TIMER OFF or CANCEL button on the remote to clear any active timer

Step 5: Check for a Lock Mode

Some split system remotes and controllers have a child lock or key lock function. When activated: button presses are ignored. The lock indicator may appear as a padlock icon or a key symbol on the remote display. Consult the remote control manual for how to deactivate the lock (usually a long press of a specific button combination).

Step 6: Power Cycle

If the unit has power at the circuit breaker and isolator, but still will not respond:

  1. Turn the circuit breaker or isolator switch off.
  2. Wait 30 seconds.
  3. Restore power.
  4. Wait 60 seconds for the unit to initialise.
  5. Try the remote again.

Some units enter a protection mode after a power outage and take 3 minutes to restart.

When the Unit Tries to Start But Then Stops

If the indoor unit powers up briefly (fan starts, display illuminates) but then shuts down and shows a fault code or error: see the fault code article for your specific brand (Daikin, Mitsubishi Electric, Fujitsu, LG, Samsung, etc.).

When to Call AEU

Call AEU on 1300 996 917 if:

  • The circuit breaker trips when the unit is switched on
  • The manual button on the indoor unit does not respond with power confirmed at the circuit breaker
  • A fault code appears on startup and the unit shuts down again
  • The unit has not been used for an extended period and now will not start (possible capacitor or control board failure)
  • The remote is confirmed working but the indoor unit infrared receiver does not respond

Related articles

Did this fix it?

If the fault is still there, lodge a ticket with your system type, install date and any fault code showing. A technician will call you within one business day.

Lodge a ticket →
Free · No obligation

Planning a new energy upgrade?

Tell us your postcode and what you are considering. We will confirm which rebates your property qualifies for and what comes off the price — no cost, no obligation.

Takes about 60 seconds
Rebates come off the price up front
One team from design to commissioning
Or call 1300 996 917
Check my rebate eligibility

Talk to our team about your property and the rebates that apply.