TCL split system air conditioners display error codes on the indoor unit display and through the T-Air app on your phone. This guide covers the most common fault codes for TCL residential split system units sold in Australia.
T-Air app
The T-Air app (available on the App Store and Google Play) connects to your TCL air conditioner via 2.4 GHz WiFi. If the app shows the unit offline after a WiFi router change, open the T-Air app, select your device, and follow the in-app WiFi reconfiguration process. The unit must be in pairing mode; follow the instructions for your specific model to activate this.
TCL fault codes
Informational codes
FD (Filter Dirty Reminder) is not a fault. This is a maintenance reminder to clean the air filter inside the indoor unit. Remove the filter, clean it gently with a vacuum or rinse with water, allow it to dry completely, and reinsert. After reinserting, hold the DISPLAY button on the remote for 3 to 5 seconds to reset the reminder (procedure varies by model; refer to your user manual).
Codes you may be able to resolve yourself
E2 (Indoor Coil Anti-Freeze Protection) means the indoor evaporator coil is approaching freezing temperature. The unit enters protection mode to prevent ice formation. Turn the mode selector to FAN ONLY (no cooling function) and run for 30 to 60 minutes to allow the coil to thaw. Clean the air filter if it has not been cleaned recently. A very dirty filter restricts airflow which causes the coil to freeze. If the E2 code returns after cleaning the filter and thawing the coil, call AEU. Persistent E2 can indicate low refrigerant, which requires an ARCtick-licensed technician.
E8 (Anti-Freezing Protection on Indoor Pipe) is similar to E2. Follow the same procedure: fan-only mode, clean filter, allow to thaw.
C5 (Outdoor Unit Communication Failure) means the indoor and outdoor units have lost communication. Check the outdoor unit circuit breaker is on. Listen for any sound from the outdoor unit when the system is turned on. If the outdoor unit has no power, investigate the circuit breaker. If both units have power but communication has failed, call AEU.
Codes requiring a technician
E1 (High Pressure Protection) means refrigerant pressure on the high-pressure side of the system has exceeded safe limits. Turn the unit off immediately. Do not restart. Check whether the outdoor unit coil is blocked with leaves or debris. Clear any blockage from around the outdoor unit and allow it to cool before trying once more. If the fault returns, call AEU. Do not open any refrigerant fittings.
E3 (Low Pressure Protection) means refrigerant pressure on the low-pressure side has dropped. This typically indicates low refrigerant charge from a slow leak. Turn the unit off. Do not restart repeatedly as operating with low refrigerant damages the compressor. Call AEU. Refrigerant work requires an ARCtick-licensed technician.
E4 (Compressor Discharge Temperature High) means the compressor is overheating. Turn the unit off immediately. Do not restart. Call AEU.
E5 (Overcurrent Protection) means an overcurrent condition was detected. Turn the unit off. Do not restart. Call AEU.
E6 (Communication Error between Indoor and Outdoor PCB) means the main control boards in the indoor and outdoor unit have lost communication. Call AEU.
E7 (Indoor Fan Motor Fault) means the indoor unit fan motor has a problem. Turn the unit off. Call AEU.
E9 (EEV or Expansion Valve Fault) means the electronic expansion valve has a fault. Call AEU.
F1 (Indoor Room Temperature Sensor Fault) means the sensor reading ambient room temperature has failed or is disconnected. The unit may still operate but without accurate temperature control. Try a restart. If the fault persists, call AEU.
F2 (Indoor Coil Pipe Temperature Sensor Fault) similar to F1 for the pipe sensor. Try a restart. If persistent, call AEU.
P1 (Voltage Protection) means supply voltage is outside the normal operating range. If other appliances are behaving unusually, contact your electricity distributor. If only the air conditioner is affected, call AEU.
P2 (Power Module Protection) means the outdoor unit power module has detected a fault. Turn the unit off immediately. Call AEU.
Unit not turning on at all
If the TCL unit shows no display and will not respond to the remote:
Check the circuit breaker for the air conditioner in your main switchboard. If it has tripped, reset it once. If it trips again, call AEU.
Check the wall power point or isolator switch near the indoor unit (if fitted on your installation).
Check the remote control batteries. Try pointing the remote directly at the indoor unit sensor window from close range.
When to call AEU
Call AEU on 1300 996 917 for: E1, E3, E4, E5, E6, E7, E9, P2 codes, any code that returns after restarting, refrigerant issues (ARCtick licence required for all refrigerant work), and any fault you cannot identify or resolve from this article.