GoodWe ESA: Using a Generator with Your System

How to use a generator with your GoodWe ESA system. Covers which models support generator input, how to connect, GoodWe's Gen Port, generator sizing requirements, and safe operation.

Solar Updated October 2026 5 min read
Quick answer

Not all GoodWe ESA inverters have a dedicated generator input. This varies by model: GW EM series (GW3648-EM, GW5048-EM): These are older single-phase models that may have a Gen Port input. Check the label on your inverter for a connection labelled GEN or Generator. GW EHB series (GW3648-EHB, GW5048-EHB, GW8048-EHB, GW10048-EHB): These single-phase hybrid models support generator input via the Gen Port. This is one of AEU's most common ESA models. GW EH series (GW3600-EH, GW5000-EH): Older EH models may have Gen Port capability. Check with AEU to confirm your specific model. GW ET / Omniverse (XS series): Three-phase models. Generator integration on these requires specialist engineering assessment. Contact AEU. If your inverter has no Gen Port and you want to use a generator as a backup, the generator would need to be connected to your main switchboard separately (not integrated into the GoodWe system). Contact AEU for options.

What Is the GoodWe Gen Port?

The Gen Port on a GoodWe ESA inverter allows a generator to be connected as an alternative AC input. When the generator is running, GoodWe uses it in a similar way to the grid: the inverter can charge the battery from the generator, and the generator can power your home via the EPS (backup) circuits.

Key point: The generator connects through the Gen Port, not to the grid-side AC input. The inverter manages the transition between generator and grid automatically.

Generator Requirements for GoodWe ESA

Generator Type

GoodWe ESA requires an inverter-type generator (also called an inverter generator). A standard generator with a direct-drive alternator produces power that is not stable enough for the GoodWe inverter to synchronise with. An inverter generator produces clean, stable AC power that meets the required voltage and frequency tolerances.

Brands like Honda EU series (EU20i, EU30is), Yamaha EF series, and Briggs and Stratton iQ series are examples of suitable inverter generators.

A standard “cheap” generator from a hardware store will not work reliably with the GoodWe Gen Port and can damage the inverter. Do not use non-inverter generators.

Generator Sizing

The generator needs to be large enough to:

  1. Power the critical loads you want to run during an outage.
  2. Have capacity left over to charge the battery.

For most homes with a GoodWe ESA system, a 3 kVA to 5 kVA inverter generator is appropriate. For larger systems or higher loads, discuss sizing with AEU.

Note: The generator does not need to power your whole house. In EPS mode, only the EPS circuit panel is supplied. Size the generator for the loads on that panel plus battery charging.

Generator Fuel

Most inverter generators use petrol. Store petrol safely and only in approved containers. For extended outages, consider a larger generator with a longer runtime or a transfer arrangement. LPG generators are also available; these can be more practical for rural properties with LPG supply.

How Generator Integration Works

When you start the generator and connect it to the GoodWe Gen Port:

  1. The GoodWe inverter detects the generator output on the Gen Port.
  2. The inverter synchronises to the generator's voltage and frequency.
  3. The inverter uses the generator to charge the battery (at a rate the generator can sustain without overloading).
  4. Critical loads on the EPS circuit are powered from the combined generator and battery output.
  5. When the battery is charged and the generator is switched off, the system runs from battery and solar until the next charging cycle.

This is particularly useful during extended grid outages when solar alone cannot maintain battery charge (e.g., multiple overcast days in a row).

Operating the Generator with GoodWe ESA

  1. Confirm the grid is off (you are in an outage) and the GoodWe is in EPS mode.
  2. Start the generator and let it warm up for 1 to 2 minutes to stabilise.
  3. Connect the generator to the Gen Port (or turn on the generator transfer switch if one has been installed by AEU).
  4. The GoodWe inverter will detect the generator and begin the synchronisation process. This takes approximately 30 to 60 seconds.
  5. Check the SEMS+ app or inverter display to confirm the generator is recognised and battery charging has started.
  6. Run the generator until the battery is at an acceptable state of charge (80% or more recommended for reliability).
  7. Switch off the generator and disconnect from the Gen Port.
  8. The GoodWe returns to running from battery and solar.

What the GoodWe Display Shows During Generator Use

In EPS mode with generator active, the SEMS+ real-time screen will show the generator as an input source (if your monitoring is still operating via mobile data). The battery will show charging. EPS circuits will show load consumption.

Generator Safety Rules

Never run a petrol generator indoors, in a garage, or under an eave. Carbon monoxide from generator exhaust is odourless and lethal. Run generators outdoors in a well-ventilated area with the exhaust directed away from windows and doors.

Keep the generator at least 5 metres from any occupied building entrance.

Do not refuel a running or hot generator.

Earth the generator if operating for extended periods (follow the generator manufacturer’s instructions).

Generator Integration Not Yet Installed?

If your GoodWe ESA has a Gen Port but the generator connection has not been set up, this requires an electrician to install the appropriate cabling and connection, and AEU to configure the Gen Port settings in the inverter. Do not connect a generator to the GoodWe Gen Port without the correct installation. Call AEU on 1300 996 917 to arrange a generator integration installation.

Call AEU on 1300 996 917 For

Checking whether your specific GoodWe model supports a generator. Arranging generator integration installation. Selecting and sizing an appropriate generator. Any issue where the GoodWe does not recognise a connected generator. Generator not charging the battery as expected.

Related articles

Did this fix it?

If the fault is still there, lodge a ticket with your system type, install date and any fault code showing. A technician will call you within one business day.

Lodge a ticket →
Free · No obligation

Planning a new energy upgrade?

Tell us your postcode and what you are considering. We will confirm which rebates your property qualifies for and what comes off the price — no cost, no obligation.

Takes about 60 seconds
Rebates come off the price up front
One team from design to commissioning
Or call 1300 996 917
Check my rebate eligibility

Talk to our team about your property and the rebates that apply.

Call 1300 996 917 Send an enquiry →