Sounds That Are Normal
Low Humming or Buzzing
A low-frequency hum or buzz from the inverter during operation is normal. It is caused by the high-frequency switching of the inverter’s power electronics (the transformer and capacitors vibrating at their switching frequency, typically 20 to 50kHz). This hum is particularly noticeable:
- In quiet conditions (early morning or evening)
- During high output (midday when the inverter is working hardest)
- Near the inverter body (the sound does not travel far)
A low hum that is consistent and has always been there is not a fault. It is a normal characteristic of the inverter.
Internal Cooling Fan
Most string inverters and hybrid inverters have an internal cooling fan that activates when the inverter temperature rises above a threshold during operation. The fan produces a noticeable hum or whirring sound.
Fan behaviour that is normal:
- Fan turns on gradually when the inverter has been producing for a while
- Fan runs at higher speed during peak midday production
- Fan may run briefly after the inverter shuts down for the evening (cooling down period)
- Fan is louder on hot days
Fan behaviour that indicates a fault:
- Fan running at full speed constantly even at low production levels or before the inverter is producing much
- Fan making a grinding, rattling, or intermittent sound (bearing fault in the fan motor)
- No fan sound at all on a hot day with high production levels, followed by overtemperature shutdown
Relay Clicks at Startup and Shutdown
A distinct click or series of clicks at inverter startup (when production begins in the morning) or shutdown (after sunset) is normal. These are the inverter’s internal relays connecting and disconnecting the grid connection. The mandatory 60-second grid connection sequence per AS/NZS 4777.2 involves relay operations that produce audible clicks.
Battery Charging and Discharging Sounds
On hybrid systems with a battery, you may hear:
- Clicking from the battery or inverter when the battery switches between charging and discharging (relay operation)
- A low hum from the battery BMS circuitry
- Occasional soft clicking from the thermal management system inside the battery
These are all normal.
Sounds That May Indicate a Problem
Loud or Unusual Buzzing That Has Changed
If the inverter has started making a louder or more high-pitched buzz than usual, or if the buzz tone has changed, this can indicate:
- A component inside the inverter (capacitor, transformer) has started to degrade
- A loose component vibrating internally
- A fan bearing fault causing the fan to vibrate unevenly
Note the specific nature of the change and call AEU on 1300 996 917 if it concerns you.
Cracking or Popping During Operation
Occasional soft pops or cracking from an inverter warming up is normal (thermal expansion of components). Frequent or loud cracking sounds are not normal and should be investigated. Turn the inverter off and call AEU on 1300 996 917.
Arcing Sound (Sizzling or Sparking)
Any sound that resembles electrical arcing (a sizzling, buzzing with a slightly sputtering quality, or a sparking sound) is not normal. Turn off the inverter at the AC isolator and DC isolator immediately and call AEU on 1300 996 917.
Sounds from the Solar Panels on the Roof
Ticking or Pinging from Panels
Solar panels expand when they heat up (daytime) and contract when they cool (morning and evening). The panel frames clicking against the mounting rails during thermal expansion is normal. This sounds like occasional irregular ticking or pinging, most noticeable at sunrise and sunset when temperature changes are rapid.
Wind Noise from Panels
If wind is blowing across the panel array, you may hear a whistling or humming from the gap between the panels and the roof. This is an aerodynamic effect, not a fault. Very loud panel noise in wind can sometimes be reduced by adding edge trim to the array, but it has no effect on performance.
Creaking from Roof Mounts
On tiled roofs, the tile hooks or flashings used to mount the racking can creak slightly as the roof temperature changes. This is a normal thermal expansion sound and is not a sign of mounting failure.
Water Dripping Inside
If you hear water dripping from the roof area near the panels after rain, ensure the roof penetrations (where mounting bolts go through the tiles) are properly sealed. This is an installation waterproofing issue, not an electrical fault. Call AEU on 1300 996 917 if you suspect a roof penetration is leaking.
When to Call AEU
Call AEU on 1300 996 917 if:
- The inverter fan has started making a grinding or rattling sound (possible bearing failure)
- The inverter hum or buzz has become noticeably louder or changed in tone
- You hear any sound resembling electrical arcing (sizzling, sputtering)
- Loud cracking or popping sounds occur during operation
- Water sounds come from the roof penetrations after rain