Solar panels work differently to most people expect when it comes to shading. Even a small amount of shade on part of the solar array can have a disproportionate effect on total output.
String Wiring and Shading Impact
In a standard solar installation, panels are wired in series strings. In a series string, the current that flows through the string is limited by the weakest panel. If one panel produces half its rated current because it is partly shaded, every panel in that string is limited to that same reduced current.
The result: a single panel partly shaded by a tree branch at 11 AM can reduce the output of an entire string by 30 to 70% during that period.
This is why shading is so important at the design stage. A well-designed system avoids placing panels where they will receive regular shading.
Bypass Diodes
Solar panels contain bypass diodes that allow current to flow around shaded cells within a panel, limiting the damage shading does to the panel’s own output. Most panels have 3 bypass diodes, so shading affects the panel in thirds.
However, bypass diodes do not help with the string current limitation problem described above. They protect individual panels from damage but do not prevent string-level output reduction.
Types of Shading
Seasonal shading: A tree or building that does not shade your panels in summer may cast shade in winter when the sun is lower in the sky. Generation reductions that appear only in winter may be seasonal shading rather than a system fault.
New growth shading: Trees grow. A tree that did not shade your panels at installation may shade them 3 to 5 years later as it grows. If generation has declined compared to previous years with similar weather, new tree growth is worth checking.
Intermittent shading: Cloud shadows, antenna, chimneys, and satellite dishes may only create shade at certain times of day. Check SEMS+ data for consistent generation dips at specific times rather than overall low output.
Bird-related: Birds perching on the panel mounting rails can create brief shadows. This is usually not significant enough to cause measurable loss.
Diagnosing Shading from SEMS+ Data
In SEMS+, view the generation graph for a clear day. If you see:
- Generation reduces at a consistent time each day (e.g. drops at 2:30 PM every sunny afternoon) - this indicates afternoon shading on part of the array from a western obstruction
- One MPPT string (PV1 or PV2) producing significantly less than the other on clear days - check whether the lower-producing string is in a shadier location
- Overall output lower than would be expected for your system size and clear sky conditions - shading is one of several possible causes
Solutions for Shading Problems
Trim or remove the tree: The most effective solution if the shading is from a tree you control. Even moderate trimming can significantly reduce the shade impact.
Panel-level power electronics: Micro-inverters (such as Enphase IQ7 or IQ8) or DC power optimisers (such as SolarEdge HD-Wave with optimisers) allow each panel to operate at its own maximum power point regardless of what other panels in the array are doing. This eliminates the string current limitation problem. However, these require retrofit at significant cost and would need a new connection application.
Accept and monitor: If the shading is minor, not increasing, and not worth the cost of solutions, accepting it and monitoring for change is a valid approach.
Repositioning panels: In some cases, moving panels to a less-shaded area of the roof is possible during a maintenance visit. This depends on roof layout and wiring capacity.
Is My Reduced Output Due to Shading or a Fault
Shading produces a characteristic pattern: output is low at consistent times of day tied to the position of obstructions, but may be normal at other times of day when those obstructions do not cast shade.
A system fault typically affects output across more of the day and may show as one string at zero output rather than reduced output. See the separate article on one string not producing in SEMS+ for fault diagnosis steps.
Contact AEU if you need help interpreting SEMS+ data to distinguish between shading effects and system faults.