What iSolarCloud Is
iSolarCloud is Sungrow’s monitoring platform. It is available as:
- Sungrow iSolarCloud app (iOS and Android, search 'iSolarCloud' in your app store)
- Web portal: isolarcloud.com.au or isolarcloud.com
Your system was registered on iSolarCloud by AEU during installation. To access your system: log in with the email address you provided at installation. If you do not know your login credentials: call AEU on 1300 996 917.
What the App Shows
Home screen energy flow diagram: Shows the current power flows between solar panels, inverter, battery (if fitted), home, and grid. Animated arrows show the direction of power flow in real time (or close to real time; there is typically a 5 to 15 minute data delay).
Reading the energy flow:
- Panels to inverter arrow: solar is generating
- Inverter to house arrow: solar is powering the home
- Inverter to grid arrow: surplus solar is being exported
- Grid to house arrow: home is importing from the grid
- Battery charging (arrow from inverter to battery): surplus solar is charging the battery
- Battery discharging (arrow from battery to home): battery is covering home load
Statistics tab: Shows daily, monthly, and lifetime production. Also shows self-consumption rate (percentage of solar consumed on-site) and self-sufficiency rate (percentage of home load covered by solar and battery).
Device tab: Shows the current status of the inverter and battery. Fault codes and alarms appear here.
Sungrow Battery Operating Modes
For SH series hybrid inverters with an SBR battery:
Self-Consumption (recommended for most customers): Battery charges from solar surplus and discharges to cover home consumption when solar is not producing. The battery will not discharge below the minimum SOC reserve (typically 10%).
To set Self-Consumption: go to Device then Settings then Working Mode in the iSolarCloud app.
Feed-in Priority: Solar exports to grid first, battery only charges if there is further surplus. Not recommended in Victoria at current feed-in tariff rates (approximately 4 to 6 cents per kWh exported vs 25 to 35 cents per kWh imported).
Backup Mode: Battery is held at 100% SOC and does not discharge for self-consumption. Only discharges during a grid outage. For customers who want to prioritise backup over daily self-consumption savings.
Forced Charge and Forced Discharge: Manual charge and discharge commands. Used for testing or TOU tariff strategies. Not a persistent mode: the system returns to the previous working mode after the command period ends.
Self-Consumption with TOU: For customers on a time-of-use electricity tariff: allows the battery to be scheduled to charge from the grid during off-peak periods and discharge during peak periods.
Changing the Backup Reserve (Minimum SOC)
The backup reserve (minimum SOC) is the SOC level the battery will not discharge below under normal conditions.
Default: 10% To change: go to Device then Battery then Min SOC in the iSolarCloud app. Setting this to 20 or 30% retains more capacity for blackout protection but reduces daily self-consumption benefit.
Note: during a grid outage, the Sungrow SH series will use the battery down to approximately 5% SOC regardless of the min SOC setting (the reserve is for normal operation only).
iSolarCloud Showing Offline
If the app shows the inverter as offline:
- Check your home Wi-Fi is functioning
- Check the communication module on the inverter: the Sungrow Wi-Fi or Ethernet data logger is a small module plugged into the side of the inverter, or is built into SH series inverters
- For SG series string inverters with a plug-in logger: confirm the logger LED is solid green (online). Amber or red indicates a connection issue.
- Reconnect the logger Wi-Fi: the Sungrow logger creates a hotspot called SG-xxxxxxxx. Connect your phone to this hotspot, then open the iSolarCloud app to reconfigure the Wi-Fi settings (go to Configuration then Local Access then Wi-Fi Setup).
- If the inverter itself has a built-in screen: confirm the inverter is running normally even if cloud monitoring is offline
Checking Fault Codes in iSolarCloud
- Open the iSolarCloud app
- Tap on Device
- Tap on Alarm Records
- The alarm list shows historical fault codes with timestamps
For Sungrow fault code meanings: see the Sungrow inverter fault codes article.
SBR Battery Status in iSolarCloud
The battery SOC (state of charge), charge and discharge power, and current mode are shown on the Home screen energy flow diagram.
For detailed battery data: go to Device then Battery then Status.
If battery SOH (state of health) data is available: it is shown in Device then Battery then History. SOH below 80% may indicate a warranty claim is appropriate (check your specific warranty terms for the threshold).
When to Call AEU
Call AEU on 1300 996 917 if:
- The inverter shows a fault code in iSolarCloud that does not clear after a power cycle
- The battery is not charging or discharging as expected with Self-Consumption mode confirmed
- iSolarCloud has been offline for more than 48 hours and basic reconnection steps have not resolved it
- You want help configuring the battery mode or backup reserve
- Battery SOH data is showing below 80%