Unlike inverter faults which show up as fault codes, solar panel problems are often silent. A panel with a significant defect may look normal from the ground and produce no fault code at the inverter. The only indication may be reduced generation that you compare against historical data, or a fault identified during a thermal imaging inspection. This is why regular visual inspection (where panels can be seen from the ground) and periodic professional thermal imaging inspections are valuable.
Hot Spots
A hot spot is a localised area of a solar panel that is much hotter than the rest of the panel during operation. Hot spots cause accelerated degradation of the affected cells and in severe cases can cause the panel to delaminate or crack.
Causes:
- A cracked or broken cell within the panel
- A shading or soiling pattern that causes one cell to be different from the rest of the string (the cell operates in reverse and dissipates energy as heat)
- A manufacturing defect in the cell connection
- Bird droppings directly over a single cell (even partial shading of one cell can cause a hot spot)
How to detect: Hot spots are not visible to the naked eye in normal conditions. They show up clearly in thermal imaging (infrared camera) inspections. They can also sometimes cause visible discolouration of the panel encapsulant (the plastic behind the cells) over time.
What to do: If a thermal imaging inspection identifies hot spots, the affected panels should be assessed for replacement under product warranty if the hot spot is caused by a manufacturing defect or early cell failure.
Microcracks
Microcracks are small cracks in silicon solar cells that are invisible to the naked eye under normal light. They form during transport, installation, or from mechanical stress such as hail impact, personnel walking on panels, or wind loading on inadequately secured panels.
Effect on output: Small microcracks may have little effect. Larger or multiple cracks can reduce a panel’s output by 5% to 20% or more as the cracked areas of the cell become disconnected.
How to detect: Microcracks are detected using electroluminescence (EL) imaging, which requires the panel to be excited with a current and photographed under the resulting light emission. This is a specialised inspection that AEU can arrange.
What to do: If microcracks are confirmed by EL imaging and are traced to manufacturing defects, a warranty claim may be available. Hail-induced microcracks are an insurance claim, not a warranty claim.
Delamination
Delamination is the separation of the layers of a solar panel. Modern panels consist of glass, encapsulant plastic, cells, another encapsulant layer, and a back sheet. Delamination occurs when these layers separate.
Signs: Visible bubbling, whitening, or separation at the edges or across the face of the panel. Sometimes a yellowish or brownish tint indicates encapsulant degradation. Delamination creates gaps that allow moisture ingress, which accelerates further deterioration.
Causes: Manufacturing defect, exposure to prolonged extreme heat, UV degradation of cheap encapsulant materials, or physical damage.
What to do: Delaminated panels have their output reduced by moisture ingress and cell exposure. Report visible delamination to AEU immediately. This is likely a product warranty claim.
Snail Trails
Snail trails are dark or discoloured lines on the surface of the panel cells that resemble tracks. They are caused by microcracks that allow silver paste from the cell contacts to migrate and oxidise under the encapsulant.
Effect on output: Snail trails can indicate microcracks and reduced cell connectivity. They suggest the panel has experienced mechanical stress.
What to do: Report visible snail trails to AEU. They indicate potential underlying cell damage. The severity depends on the extent and location of the snail trails.
Snail Trails vs Normal Discolouration
Normal panel soiling (dust, pollen, bird droppings) sits on the glass surface and can be cleaned. Snail trails and delamination are inside the lamination layers and cannot be cleaned off. If you wipe the panel glass and the discolouration does not come off, it is inside the panel and should be reported to AEU.
When to Contact AEU
- You can see visible discolouration, bubbling, or separation on a panel
- Your generation has dropped and one string is consistently lower than the other
- A professional inspection has identified hot spots or microcracks
- A panel has been struck by hail and you can see physical damage or cracking
- You see any physical damage to the glass surface of a panel
Photographs from the ground are helpful when you contact AEU. Do not go on the roof to inspect panels without proper fall arrest equipment.